<?xml version="1.0" encoding="utf-8"?>
<feed xmlns="http://www.w3.org/2005/Atom">
  <title>龙松检测设备</title>
  <link href="https://www.longsongtest.com/feed.xml" rel="self"/>
  <link href="https://www.longsongtest.com/"/>
  <updated>2026-10-28T08:45:04.444Z</updated>
  <id>https://www.longsongtest.com/</id>
  <entry>
    <title>环境试验设备在汽车零部件与新能源行业的应用</title>
    <link href="https://www.longsongtest.com/news/environmental-testing-automotive-new-energy/"/>
    <id>https://www.longsongtest.com/news/environmental-testing-automotive-new-energy/</id>
    <updated>2026-10-28T08:45:04.444Z</updated>
    <published>2026-07-06T01:04:00.000Z</published>
    <summary>汽车零部件与新能源产品对温度、湿度、振动与腐蚀环境更为敏感。本文梳理高低温、冷热冲击、湿热与盐雾设备在研发验证中的典型应用。</summary>
  </entry>
  <entry>
    <title>盐雾、紫外、氙灯：三种耐候老化试验怎么选</title>
    <link href="https://www.longsongtest.com/news/salt-spray-uv-xenon-comparison/"/>
    <id>https://www.longsongtest.com/news/salt-spray-uv-xenon-comparison/</id>
    <updated>2026-10-28T08:45:04.444Z</updated>
    <published>2025-12-23T05:22:00.000Z</published>
    <summary>盐雾、紫外与氙灯分别模拟腐蚀、短波紫外与全光谱太阳辐射。理解三种试验的失效机理与标准适用范围，才能制定有效的耐候验证方案。</summary>
  </entry>
  <entry>
    <title>车载摄像头IP69K过了，冬天洗车为何还进水</title>
    <link href="https://www.longsongtest.com/news/camera-ip69k-winter-carwash-water-ingress/"/>
    <id>https://www.longsongtest.com/news/camera-ip69k-winter-carwash-water-ingress/</id>
    <updated>2026-10-22T12:11:59.663Z</updated>
    <published>2026-10-18T08:07:00.000Z</published>
    <summary>台架 IP6K9K 通过，装车后冬天洗车仍起雾进水。高压热水喷淋、低温冻融、透气膜、接插件和镜头加热，任何一处都能让水汽留在模组里。</summary>
  </entry>
  <entry>
    <title>步入式试验室与冷热冲击箱批量发运</title>
    <link href="https://www.longsongtest.com/news/2026-walk-in-thermal-shock-shipment/"/>
    <id>https://www.longsongtest.com/news/2026-walk-in-thermal-shock-shipment/</id>
    <updated>2026-10-28T08:45:04.444Z</updated>
    <published>2026-10-10T04:43:00.000Z</published>
    <summary>10 月中旬，三台步入式恒温恒湿试验室和两台三箱式冷热冲击试验箱完成出厂调试，陆续发往江苏、广东和安徽客户现场。</summary>
  </entry>
  <entry>
    <title>车载屏高温高湿后白斑，是偏光片还是背光</title>
    <link href="https://www.longsongtest.com/news/automotive-display-white-spot-polarizer-backlight/"/>
    <id>https://www.longsongtest.com/news/automotive-display-white-spot-polarizer-backlight/</id>
    <updated>2026-10-22T12:11:59.666Z</updated>
    <published>2026-10-01T02:34:00.000Z</published>
    <summary>85/85 后屏幕出现白斑，别急着换液晶。偏光片脱胶、背光膜片受潮、结构应力、凝露和 LED 热斑，都会在白画面留下不一样的斑。</summary>
  </entry>
  <entry>
    <title>氙灯 550 W/m²，别把全光谱当成紫外辐照</title>
    <link href="https://www.longsongtest.com/news/xenon-550w-irradiance-full-spectrum/"/>
    <id>https://www.longsongtest.com/news/xenon-550w-irradiance-full-spectrum/</id>
    <updated>2026-10-04T00:00:00.000Z</updated>
    <published>2026-09-16T09:43:00.000Z</published>
    <summary>GB/T 1865-2009 仍现行，但 2027-02-01 起将被 GB/T 23987.2-2026 替代。氙灯 550 W/m² 通常是 300–800 nm 全光谱，不是 300–400 nm 紫外；黑标温度、滤光片和辐照度校准决定结果，报告应记录波段、设定值、累计剂量与校准信息，避免误判。</summary>
  </entry>
  <entry>
    <title>冷热冲击 3 分钟和 15 秒转换，差别在哪</title>
    <link href="https://www.longsongtest.com/news/thermal-shock-conversion-time-dwell/"/>
    <id>https://www.longsongtest.com/news/thermal-shock-conversion-time-dwell/</id>
    <updated>2026-10-14T00:00:00.000Z</updated>
    <published>2026-07-11T03:50:00.000Z</published>
    <summary>GB/T 2423.22-2012 试验 Na 要求转换时间不宜超过 3 min，驻留默认 3 h；15 秒是设备能力或客户规范，不是标准强制值。转换越快，瞬态热应力越大；驻留够不够，要看样品温度稳定，不是箱体到温。报告要写实测转换时间和稳定判据。</summary>
  </entry>
  <entry>
    <title>什么是可靠性试验</title>
    <link href="https://www.longsongtest.com/news/what-is-reliability-testing/"/>
    <id>https://www.longsongtest.com/news/what-is-reliability-testing/</id>
    <updated>2026-10-28T08:45:04.444Z</updated>
    <published>2026-06-28T07:41:00.000Z</published>
    <summary>可靠性试验通过实验室或现场试验调查、分析与评价产品可靠性，覆盖工作寿命、贮存寿命、环境应力与失效分析，是产品定型与改进的重要依据。</summary>
  </entry>
  <entry>
    <title>光伏 DH1000：1000 小时湿热试验怎么排</title>
    <link href="https://www.longsongtest.com/news/pv-module-dh1000-damp-heat/"/>
    <id>https://www.longsongtest.com/news/pv-module-dh1000-damp-heat/</id>
    <updated>2026-10-10T00:00:00.000Z</updated>
    <published>2026-06-06T06:37:00.000Z</published>
    <summary>IEC 61215 系列 DH1000 要求 85℃/85%RH、1000h，连续运行约 42 天。大尺寸组件进箱、承重、水质、结露和中途开门恢复都要提前排，设备按满载和长期运行验收。</summary>
  </entry>
  <entry>
    <title>IP5X 和 IP6X 差的不只是防尘等级</title>
    <link href="https://www.longsongtest.com/news/ip5x-ip6x-dust-test-talc-negative-pressure/"/>
    <id>https://www.longsongtest.com/news/ip5x-ip6x-dust-test-talc-negative-pressure/</id>
    <updated>2026-10-18T00:00:00.000Z</updated>
    <published>2026-05-23T08:26:00.000Z</published>
    <summary>GB/T 4208-2017（含 2024 年修改单）下，IP5X 允许少量进尘，IP6X 要求尘密。滑石粉 2 kg/m³、压差不超过 2 kPa、抽气量按壳体容积的 80 倍；现场最容易做错的是压差、抽气量和试验后的恢复。试验后先泄压静置再开盖，别让二次扬尘干扰判定。</summary>
  </entry>
  <entry>
    <title>密封条压缩永久变形合格，整车淋雨漏水，夹具错在哪</title>
    <link href="https://www.longsongtest.com/news/weatherstrip-compression-set-leak/"/>
    <id>https://www.longsongtest.com/news/weatherstrip-compression-set-leak/</id>
    <updated>2026-10-22T11:00:20.494Z</updated>
    <published>2026-05-14T07:02:00.000Z</published>
    <summary>压缩永久变形 22% 仍漏水的案例不少，问题多在夹具压缩率和边界条件。拆开看 70℃×24 h 试验与实车安装的差异，给出淋雨线参数、低温硬化和排水孔的排查顺序。</summary>
  </entry>
  <entry>
    <title>盐雾试验国家标准</title>
    <link href="https://www.longsongtest.com/news/salt-spray-test-national-standard/"/>
    <id>https://www.longsongtest.com/news/salt-spray-test-national-standard/</id>
    <updated>2026-10-28T08:45:04.444Z</updated>
    <published>2026-04-16T06:19:00.000Z</published>
    <summary>介绍盐雾试验国家标准对试验溶液、温度、喷雾量、试样摆放、试验时间与腐蚀判定的要求，适用于金属覆盖层与表面处理件的耐蚀性评价。</summary>
  </entry>
  <entry>
    <title>配电柜铜排盐雾测试怎么选</title>
    <link href="https://www.longsongtest.com/news/busbar-salt-spray-selection/"/>
    <id>https://www.longsongtest.com/news/busbar-salt-spray-selection/</id>
    <updated>2026-10-23T05:52:55.470Z</updated>
    <published>2026-03-28T07:22:00.000Z</published>
    <summary>镀银铜排盐雾96小时发暗，接触电阻升高。镀银层厚度、盐雾条件、清洗方式和电阻复测，决定铜排能不能装进柜子。</summary>
  </entry>
  <entry>
    <title>2026 年验收湿热箱，条款要跟着新标准改</title>
    <link href="https://www.longsongtest.com/news/gb-t-10586-2025-chamber-acceptance/"/>
    <id>https://www.longsongtest.com/news/gb-t-10586-2025-chamber-acceptance/</id>
    <updated>2026-10-12T00:00:00.000Z</updated>
    <published>2026-03-24T04:06:00.000Z</published>
    <summary>GB/T 10586-2025 替代 2006 版，GB/T 10592-2023 替代 2008 版。验收看负载、布点、稳定时间和开门恢复，别只抄铭牌均匀度，校准按 JJF 1101-2019。</summary>
  </entry>
  <entry>
    <title>恒温恒湿试验箱的简介</title>
    <link href="https://www.longsongtest.com/news/constant-temperature-humidity-chamber-introduction/"/>
    <id>https://www.longsongtest.com/news/constant-temperature-humidity-chamber-introduction/</id>
    <updated>2026-10-28T08:45:04.444Z</updated>
    <published>2026-03-13T06:19:00.000Z</published>
    <summary>恒温恒湿试验箱通过制冷、加热、加湿与除湿系统协同工作，为电子、材料与零部件提供稳定的温湿度环境，是环境可靠性试验的基础设备。</summary>
  </entry>
  <entry>
    <title>电源模块-40℃启动打嗝，储存和启动哪个更严</title>
    <link href="https://www.longsongtest.com/news/power-module-minus40-startup/"/>
    <id>https://www.longsongtest.com/news/power-module-minus40-startup/</id>
    <updated>2026-10-22T14:19:00.934Z</updated>
    <published>2026-02-23T02:05:00.000Z</published>
    <summary>冷透后满载上电，输出起来又掉，空载却正常。打嗝多半是输入电容 ESR 升高触发欠压锁定；储存冷启动比低温运行更严，大纲要写清是哪一种。</summary>
  </entry>
  <entry>
    <title>药品稳定性试验：25℃/60%RH还是30℃/65%RH</title>
    <link href="https://www.longsongtest.com/news/drug-stability-25-60-vs-30-65/"/>
    <id>https://www.longsongtest.com/news/drug-stability-25-60-vs-30-65/</id>
    <updated>2026-10-23T02:19:54.000Z</updated>
    <published>2026-02-19T01:54:00.000Z</published>
    <summary>长期条件选 25/60 还是 30/65，要看目标市场气候带和申报资料，不是箱体能跑哪个。加速 40/75 六个月，中间条件 30/65 只在特定情况加。</summary>
  </entry>
  <entry>
    <title>连接器盐雾24h和96h，判据到底差在哪</title>
    <link href="https://www.longsongtest.com/news/connector-salt-spray-24h-96h/"/>
    <id>https://www.longsongtest.com/news/connector-salt-spray-24h-96h/</id>
    <updated>2026-10-22T14:19:00.932Z</updated>
    <published>2026-02-16T03:48:00.000Z</published>
    <summary>24 h 看漏镀和清洗残留，96 h 才开始暴露镀层孔隙和基体腐蚀。时长不同，判据也不能共用一套；接触电阻和插拔力比“有没有红锈”更关键。</summary>
  </entry>
  <entry>
    <title>连接器盐雾480h没红锈，插拔力却超差，镀层厚度够吗</title>
    <link href="https://www.longsongtest.com/news/automotive-connector-salt-spray-insertion-force/"/>
    <id>https://www.longsongtest.com/news/automotive-connector-salt-spray-insertion-force/</id>
    <updated>2026-10-22T11:00:20.490Z</updated>
    <published>2026-02-05T08:11:00.000Z</published>
    <summary>480 h 盐雾外观无红锈，插拔力却往上走。问题常出在端子镀层、盐雾后清洗和测试顺序。按现场复盘，拆开看镀层厚度、微动腐蚀和端子应力松弛。</summary>
  </entry>
  <entry>
    <title>随机振动控制点差3dB，样品受力差多少</title>
    <link href="https://www.longsongtest.com/news/random-vibration-control-3db-fixture/"/>
    <id>https://www.longsongtest.com/news/random-vibration-control-3db-fixture/</id>
    <updated>2026-10-22T12:11:59.665Z</updated>
    <published>2026-01-24T09:05:00.000Z</published>
    <summary>3 dB 不是“差一点”。随机振动里 3 dB 等于 PSD 翻倍、GRMS 乘 1.41；控制点、夹具共振和测点位置不同，样品上的应力可能差得更多。</summary>
  </entry>
</feed>
